PATH=SYNCHRONOUS, EDGSEL=NO_EVT_OUTPUT
Channel n
| EVGEN | Event Generator Selection  |  
| PATH | Path Selection 0 (SYNCHRONOUS): Synchronous path 1 (RESYNCHRONIZED): Resynchronized path 2 (ASYNCHRONOUS): Asynchronous path  |  
| EDGSEL | Edge Detection Selection 0 (NO_EVT_OUTPUT): No event output when using the resynchronized or synchronous path 1 (RISING_EDGE): Event detection only on the rising edge of the signal from the event generator when using the resynchronized or synchronous path 2 (FALLING_EDGE): Event detection only on the falling edge of the signal from the event generator when using the resynchronized or synchronous path 3 (BOTH_EDGES): Event detection on rising and falling edges of the signal from the event generator when using the resynchronized or synchronous path  |  
| RUNSTDBY | Run in standby  |  
| ONDEMAND | Generic Clock On Demand  |